TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download
Page 116 of 176
TM 9-1240-216-34 4-18. BOARD ASSEMBLY AND GROUND WIRE ASSEMBLY INSTALLATION (CONT) NOTE This procedure is for installation of either board assembly. FRAME 2 Step 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Procedure NOTE If ground wire is the only item to be installed, go to step 4. Place screw (1) through lockwasher (2) and tagged wire terminal lug (3). Using screwdriver, put screw (1) into terminal (4) of board assembly (5) while making sure the numbers on, the tags match the number of the terminals (4). Remove tags from the wires. Using screwdriver, install screw (1), lockwasher (2) and ground wire to board assembly (5). Slide terminal housing (6) over board assembly (5). Place long screw (7) through lockwasher (8), board assembly (5), spacer (9), and terminal housing (6). Place terminal housing (6) in body assembly (10). Using screwdriver, put in and tighten long screw (7) into body assembly (10). Place short screw (11) through lockwasher (12) and terminal housing (6). Using screwdriver, put short screw (11) into body assembly (10). NOTE FOLLOW-ON MAINTENANCE Install cover (para 4-l3). Do checkout procedure (Vol I, para 2-2) END OF TASK Para 4-18 Cont 4-32 Vol II