TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download
Page 106 of 176
TM 9-1240-216-34 4-15. BODY COVER INSTALLATION TOOLS: Hydraulic sealing gun 1/4" flat tip screwdriver Pocket knife SUPPLIES: Sealing compound (item 8, App A) Dry cleaning solvent (item 9, App A) Cloth (item 1, App A) PERSONNEL: One REFERENCES: JPG 4lC for sealing procedures EQUIPMENT CONDITION: Body assembly on work bench; power disconnected FRAME 1 Step 1. 2. 3. 4. Procedure WARNING Dry cleaning solvent can catch on fire. Keep it and all material that can catch on fire away from flames. Use only in room with a lot of fresh air. Using pocket knife, scrape off old sealing compound. Using dry cleaning solvent on cloth, clean off any remaining old sealing compound from cover (1) and body assembly (2). Place cover (1) on body assembly (2). Using screwdriver, put in and tighten 15 lockwashers (3) and 15 screws (4). Using sealing gun, force sealing compound in 8 sealing holes (5) of cover (1) until completely sealed (JPG). NOTE FOLLOW-ON MAINTENANCE Do final inspection (para 5-1). END OF TASK Para 4-15 4-22 Vol II