TB-9-2350-368-25 Powerplant Test Stand M113A2 M113A3 M548A1 M548A3 Download

Page 54 of 120

TB 9-2350-368-25 2-40 h. Starter Cable (M113A2/M548A1) Bill Of Materials Item Nomenclature Part Number NSN Qty 1 Receptacle Connector 7715781 1 2 Nonmetallic Bushing 8376776 5365-00-318-8184 1 3 Bushing Retainer Nut 7723308 5935-00-333-9414 1 4 Lug Terminal MS20659-135 5940-00-115-5001 1 5 Electrical Wire M13486/1-14 6145-00-705-6674 A/R 6 Band Marker M43436/1-1 9905-00-752-4649 2 1. Measure from the M113A2 engine harness to power bus bar. 2. Connect AWG 1/0 electrical lead (5) measured in step 1, to receptacle connector (1-3). 3. Label leads (5), using band markers (6) as circuit 6. 4. Install lug terminal (4) on lead (5). See Figure 2-25. Figure 2-25. Starter Cable (M113A2/M548A1)