TB-9-2350-368-25 Powerplant Test Stand M113A2 M113A3 M548A1 M548A3 Download
Page 102 of 120
TM 9-2350-368-25 5-4 5. Turn master switch on. Check transmission harness at the end. You should get the following readings: SL position Battery voltage on pins BDEJ R position Battery voltage on pins BCEJK PV position Battery voltage on pins BDEJK 1-4 position Battery voltage on pins ACJK 1-3 position Battery voltage on pins ACEFNJK 1-2 position Battery voltage on pins ACENJK 1 position Battery voltage on pins ACEJK 5-4. A2 WIRING HARNESS 1. Turn master switch on. Check four wire regulator harness at the end that connects to the regulator. You should get the following readings: Pin A Not used Pin B Circuit number 1 0 volts Pin C Circuit number 2 0 volts Pin D Circuit number 2A 0 volts Pin E Circuit number 3A 0 volts Pin F Not used Pin G Not used 2. Turn master switch on. Check three wire regulator harness at the end that connects to the regulator. You should get the following readings: Pin A Circuit number 2 Battery voltage Pin B Not used Pin C Circuit number 3 0 volts Pin D Not used Pin E Not used Pin F Circuit number 1B 0 volts 3. Turn master switch on. Check accessory harness at the end. You should get the following readings: Pin A Not used Pin B Circuit number 1B 0 volts Pin C Circuit number 406 0 volts Pin D Circuit number 34 Battery voltage Pin E Circuit number 33 Battery voltage Pin F Circuit number 1A Battery voltage Pin G Circuit number 327 Battery voltage Pin H Circuit number 74A 0 volts 4. Turn master switch on. Check starter harness at the end. You should get the following readings: Pin A Circuit number 6 Battery voltage