TB 9-2350-277-40&P-2 REWORK PROCEDURES 0004 00 0004 00-1 THIS WORK PACKAGE COVERS: Disassemble Power Plant Upper Rear Access Panel (page 0004 00-1). Assemble Power Plant Upper Rear Access Panel (page 0004 00-2). INITIAL SETUP: Maintenance Level Sustainment Tools and Special Tools General Mechanic’s Tool Kit (WP 0012 00, Item 5) Materials/Parts Crew II Modification Kit (12498026) Personnel Required Mechanic Equipment Conditions Power plant upper rear access panel removed (WP 0003 00) DISASSEMBLE POWER PLANT UPPER REAR ACCESS PANEL 1. Remove screw (4), self-locking nut (8), and spring tension clip (5) from angle bracket (6). Discard screw and nut. Retain spring tension clip for reassembly. 2. Remove two screws (10), self-locking nuts (9), and bracket assembly (11) from angle bracket (6). Discard screws and nuts. Retain bracket assembly for reassembly. 3. Remove four screws (1), self-locking nuts (7), two mounting plates (2), and angle brackets (6) from power plant upper rear access panel (3). Discard screws, nuts, and one angle bracket. Retain mounting plates and one angle bracket for reassembly. Figure 1. Disassemble Power Plant Upper Rear Access Panel