TB 9-2350-277-40&P-1 INSTALLATION PROCEDURES – Continued 0005 00 0005 00-18 8. Locate ground strap (29) on the inside of enclosure assembly (79). Cut the tie strap and route ground strap out the back of the enclosure assembly (79). 9. Pull and position ground strap (29) to attach to rear screw (36) on cable guard (35). 10. Remove screw (36), lockwasher (37), and washer (18) from cable guard (35). Discard lockwasher. NOTE Mount ground strap next to head of screw. 11. Install screw (36), ground strap (29), lockwasher (37), and washer (18) on cable guard (35). 12. Attach enclosure assembly cover (82) to enclosure assembly (79) using four screws (81), lockwashers (16), and washers (15). Figure 17. Ground Strap and Cable Guard Installation