LO-9-2320-260-12 Lubrication Order for M113A2 M577A2 M106A2 M125A2 M1059 M1064 M1068 Download

Page 30 of 42

LUBRICATION ORDER LO 9-2350-261-12 10 JULY 1990 (Supersedes LO 9-2350-261-12, July 1985) NOTES WARNING Dry cleaning solvent burns easily, can cause Clean fittings with dry cleaning solvent skin rash, and can give off harmful vapors. To (PD-680, Type II) prior to lubrication. avoid injury, keep away from open fire and use Check /lubricate grease fitting points after in well-ventilated area. Wear protective clothing washing or fording. and rubber gloves. NOTE 1. UNIVERSAL JOINTS. Every 150 hours, 1500 When grease fitting will not accept GAA, notify miles, or semiannually, lubricate all universal unit maintenance. joints and propeller shaft bearings with grease (GAA) (6 places). Each universal joint spider has two fittings, but only one of each pair of fittings requires lubrication. CARD 23 of 32