LO-9-2320-260-12 Lubrication Order for M113A2 M577A2 M106A2 M125A2 M1059 M1064 M1068 Download

Page 23 of 42

NOTES 5. HARD TIME INTERVAL. If AOAP Labora- 1. Do NOT mix OE/HDO 15W40 with single tory support is not available, drain trans- grade lubricants. mission every 150 hours, 1500 miles, or semiannually. Drain only when hot after 2. Complete oil change with filters is re- operation. quired when converting from OE/HDO 15W40 to OEA (or OEA to OE/HDO 6. TRANSMISSION OIL FILTER. Replace 15W40) in accordance with Temperature filter element (TM 9-2350-261-20) each Key Chart. time a transmission oil change is re- quired. The filter element will be changed NOTE on a hard time interval. When the AOAP Park carrier on level ground to check oil laboratory identifies to replace the oil, levels. Check/lubricate all oil and grease reset the hard time interval for the filter fitting points after washing or fording. element. CAUTION NOTE Transmission can be damaged if filled Visual inspection of transmission oil above FULL mark. Check transmission should not be justification to replace oil. oil level before operation. Transmission Modern detergent transmission oils may oil level should not be above FULL marks appear dark in color due to additives. on gage rod. 7. TRANSMISSION OIL DRAIN AND FILTER 3. TRANSMISSION OIL LEVEL. Before op- ELEMENT REPLACEMENT. eration, check transmission oil level. Re- NOTE move driver’s access panel (TM 9-2350- 261-10). Add oil (OE/HDO), as needed, to Drain oil only when hot after operation. bring oil level between ADD and FULL Allow oil to drain thoroughly for 1 hour, if marks on gage rod. With engine discon- time permits. nect engaged, start and run engine at 800 a. Remove hull bottom access cover rpm for 3 to 5 minutes with shift lever in 2- (TM 9-2350-261-20). 3 and brakes locked to allow transmission b. Place suitable container under trans- oil to reach normal operating temper- mission drain plug. ature. With engine idling, move shift lever through all ranges to assure complete c. Remove plug from transmission and drain oil into container. Allow oil to circulation. Return shift lever to N, and drain thoroughly for 1 hour, if time check transmission oil level with engine operating at 1500 rpm. permits. d. Inspect plug and oil for metallic pafli- 4. FREQUENCY OF AOAP SAMPLE: Every cles. If metal chips are found, notify 60 days, obtain a sample of transmission direct support maintenance. oil and send to the nearest AOAP Labora- tory. For additional reference see TB 43- 0210 and TM 9-2300-422-23&P. Routine samples are to be submitted at pre- scribed intervals. Samples should be tak- en as near the prescribed interval as possible. If sampling at the prescribed interval is not always possible, a 10 per- cent variance, before or after the sched- uled interval date or miles for sampling, is permissible. The need for on-condition oil changes will be determined by the AOAP Laboratory. Hard time intervals will al- ways apply to the transmission oil filter element. CARD 16 of 32 Change 3