LO-9-2320-260-12 Lubrication Order for M113A2 M577A2 M106A2 M125A2 M1059 M1064 M1068 Download

Page 10 of 42

LUBRICATION ORDER LO 9-2350-261-12 10 JULY 1990 (Supersedes LO 9-2350-261-12, July 1985) 5. 6. 7. 8. 9. 10. 11. 12. 13. Place range selector in N position and keep engine running. Remove driver’s power plant access panel (TM 9-2350-261-10). With engine running remove dust caps from engine and transmission oil sam- pling valves. Open sample valve on engine oil filter and drain a small amount of oil into a container to clear valve of grit and contamination. (Properly dispose of container and oil upon completion of sample taking.) Fill sampling bottle to the neck shoulder and seal it. Attach DA Form 2026 to sample bottle. Close oil sample valve and install dust cap. Take oil sample from transmission in the same manner (steps 7 thru 9). Stop engine (TM 9-2350-261-10). Install driver’s compartment power plant access panel and secure carrier. Deliver sample bottles to the unit AOAP monitor. NOTE For Iocation of nearest AOAP Laboratory and complete information about AOAP, refer to TB 43-0210. LUBRICATION TABLE The lubrication table on cards 4 and 5 summarizes the types of lubricants and quantities used on the carrier. Charts A thru E, referred to in the table, are located at the back of this Lubrication Order. Change 1 CARD 3 of 32