TM-9-2920-258-30&P Technical and Parts Manual for 5520AB Generator Download

Page 12 of 76

TM 9-2920-258-30&P 2-5 TROUBLESHOOTING PROCEDURES (cont.) 3 Place one multimeter lead on pin "F" and one multimeter lead on point "A" (stator assembfy). Check for continuity. If circuit is open, repair or replace pin as required. Follow above procedure to check pin "D," and then pin "B." 4 Place one multimeter lead on pin "E” and one multimeter lead on pin "D.” Check for continuity. If the circuit is open, repair or replace pin "E” or “D” as required. 2-4