TM-9-2920-225-34 Technical Manual for Generators AMA5102UT 3002AC and 3002AD Download

Page 77 of 262

TM 9-2920-225-34 FRAME 2 1. Take off three nuts (1). 2. Take out capacitor panel (2). 3. Tag all leads in housing (3). 4. Take off five nuts (4), six flat washers (5), and two lockwashers (6). 5. Take all leads off stator terminal (7) and take stator (8) away from housing (3). GO TO FRAME 3 TA103562 2-61