TM-9-2920-225-34 Technical Manual for Generators AMA5102UT 3002AC and 3002AD Download
Page 247 of 262
TM 9-2920-225-34 1. Set MAIN POWER switch (1) to ON position. 2. Press START button (2) and hold it for three seconds. Turn DRIVE SPEED control (3) to right until TACHOMETER (4) reads 2000 RPM. 3. Turn TACHOMETER SELECTOR switch (5) to CAL position and turn TACHOMETER CONTROL (6) to right until TACHOMETER (4) reads generator speed. Refer to para 2-23d. 4, Turn DRIVE SPEED control (3) until TACHOMETER (4) reads 2000 RPM. 5. Place BATTERY selector (7) in 24V position. 6. Set 100A LOAD switch (8) and MASTER LOAD (9) to ON position. GO TO FRAME 2 I [ TA 103724 2-231