TM 9-2920-225-34 b. Removal. FRAME 1 I 1. Take out output switch access plug (1) from regulator (2). 2. Take out six screws (3) and lockwashers (4). 3. Take off regulator (2) and preformed packing (5). NOTE Do not take apart regulator (2). END OF TASK TA 103500 2-2