TM 9-2920-225-34 1. Tag two leads (1) on negative heat sink stud (2). 2. Take off nut, lockwasher, and flat washer (3). 3. Take off two leads (1) from negative heat sink stud (2). 4. Take brush holder (4) out of housing (5). GO TO FRAME 6 TA 103599 2-99