TM-9-2350-358-BD M109A6 Battlefield Damage Assessment and Repair Download
Page 55 of 343
TM 9-2350-358-BD 3-10. WIRES, BROKEN - CONTINUED Materials/Tools: • Crimping tool, terminal (found in M2/3 generic BDR kit, Section III, Appendix C) • Gun, thermal • Insulation sleeving, electrical (item 37, Appendix C) • Tape, insulation, electrical (item 63, Appendix C) • Terminal, lug, crimp style (item 67, Appendix C) Procedural Steps: NOTE If terminal lug is used for spicing, select barrel diameter large enough to accept both wires. 1. Cut terminal lug flush with barrel. 2. Cut insulation sleeve 1 inch longer than barrel. 3. Strip ends of broken wires. 4. Install insulation sleeve over one end of broken wire. 5. Insert wires into prepared splice barrel and crimp to secure wires. 6. Slide sleeve over splice or use tape to insulate conductor. 7. Apply heat to shrink material. 8. Tie off ends of non-shrink sleeve. 9. Record BDAR action taken. When mission is complete, as soon as practical, repair the equipment/system using standard maintenance procedures. Option 3 Limitations: None 3-10