TM 9-2350-358-BD SECTION II. FABRICATED TOOLS - CONTINUED Description: Jumper Wires NOTE This jumper wire is not for use with test jack connectors. It can short-circuit equipment. (For test jack jumper wire, see procedure being performed.) Materials/Tools: Wire, electrical, 10 AWG (scavenge from available source) Jumper Wires Fabrication/Test Procedure: 1. Strip 1/2-inch of insulation from both ends of wire. 2. Twist ends for insertion directly into connector sockets and tape in place. NOTE If wire is a larger AWG than required, do step 3. If wire is a smaller AWG than required, do step 4. 3. Pull back strands as required and clip off; tape over exposed wire and tape in place. 4. Strip more insulation from ends, fold ends over until proper size is obtained, and tape in place. B-5/(B-6 blank)