TM-9-2350-358-BD M109A6 Battlefield Damage Assessment and Repair Download

Page 303 of 343

TM 9-2350-358-BD APPENDIX B SPECIAL OR FABRICATED TOOLS BDAR FIXES SHALL BE USED ONLY IN COMBAT OR FOR TRAINING AT THE DISCRETION OF THE COMMANDER. (AUTHORIZED TRAINING FIXES ARE LISTED IN APPENDIX E.) IN EITHER CASE, DAMAGES SHALL BE REPAIRED BY STANDARD MAINTENANCE PROCEDURES AS SOON AS PRACTICABLE. SECTION I. INTRODUCTION B1. SCOPE This appendix lists fabricated tools recommended for the support of the M109A6 howitzer in a combat environment. B-2. GENERAL The fabricated tools listed in Section II are tools to be used for testing when test equipment is not available. SECTION II. FABRICATED TOOLS Description: Voltmeter, 18-30 V dc, 5 V dc or less NOTE The voltage rating of the bulb should be close to the value of the expected voltage being measured. Materials/Tools: Bulb Wire, electrical, length as required, two pieces Solder Soldering iron Voltmeter Fabrication/Test Procedure: 1. Solder a wire to center terminal and another wire to case of bulb. B-1