TM-9-2350-358-BD M109A6 Battlefield Damage Assessment and Repair Download

Page 282 of 343

TM 9-2350-358-BD 13-9. COAXIAL CABLE REPAIR General Information: This procedure gives instructions and identifies materials recommended for repair of coaxial or other shielded cables when standard replacement parts are not available. Option 1: Using matching plug and jack. Limitations: None Personnel/Time Required: 1 soldier 0.4 hour Materials/Tools: See illustrations in this procedure for materials required. Other Options: Reference shielded cable repair procedures in Chapter 3. Procedural Steps: NOTE Do not attempt to repair broken or damaged coaxial cables unless absolutely necessary. Replace the entire cable whenever possible. 1. If replacement is not practical, install a matching plug and lack of the proper size and type for splicing the damaged or broken part. 2. Record BDAR action taken. When mission is complete, as soon as practical, repair the equipment/system using standard maintenance procedures. 13-14