TM-9-2350-358-BD M109A6 Battlefield Damage Assessment and Repair Download
Page 242 of 343
TM 9-2350-358-BD 11-13. HYDRAULIC TUBE AND HOSE ISOLATION - CONTINUED Procedural Steps: 1. Remove broken tube from adapter. WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use it in well- ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. 2. Coat threads of pipe plug with sealing compound. 3. Install cap on adapter. 4. Record the BDAR action taken. When mission is complete, as soon as practical, repair the equipment/system using standard maintenance procedures. Option 4: High-pressure line repair (tube isolation) using flattened tube end. Limitations: None 11-24