TM-9-2350-358-BD M109A6 Battlefield Damage Assessment and Repair Download

Page 232 of 343

TM 9-2350-358-BD 11-11. HYDRAULIC TUBE AND HOSE REPAIR (HIGH PRESSURE) - CONTINUED WARNING Tubing must be fully inserted into fitting and the nut tightened as specified in this procedure to prevent leakage and injury to personnel from high pressure hydraulic fluid In the event of fitting blow-off. Excessive tightening on the nut beyond the recommended level may affect performance. 8. Install the nut onto the nipple hand tight. Ensure tube is fully inserted into the fitting (bottom out) Mark the nut in relation to the adapter. Tighten nut 1-1/2 turns. NOTE The ORS tube fitting assemblies are designed for reuse and can be reinstalled by tightening nut until a sharp increase in resistance is felt (approximately 1/4 turn beyond hand tight) If connections must be temporarily disassembled, use a threaded plug to contain the ORS tube fitting components and keep contaminants from entering the system 9. Fill and bleed hydraulic system. 10. Record the BDAR action taken. When mission is complete, as soon as practical, repair the equipment/system using standard maintenance procedures. Option 3: High pressure tubing repair small damage (1/4-inch or less). Limitations: None Personnel/Time Required: 1 soldier 0.5 - 2.0 hours 11-14