TM-9-2350-311-34-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 51 of 352
TM 9-2350-311-34-1 e. PERSONNEL VENTILATION BLOWER INSUFFICIENT AIR CIRCULATION WITH BLOWER ON Disasemble personnel ventilation blower and check for seized bearings (para 9-1). Are bearings seized? Replace seized bearings and verify that problem is solved (para 9-1). Check radio noise filter assembly for continuity (para 9-1). Is continuity present? Replace personnel ventilating fan (para 9-1). Replace radio noise filter assembly (para 9-1). END OF TASK 3-11