TM-9-2350-311-34-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 267 of 352
14 15 16 17 TM 9-2350-311-34-1 Place heater exhaust assembly (29) with hose clamp (30) in mounted position between coolant heater mounting brackets (20). Install inlet elbow (31) and outlet elbow (32) to coolant heater assembly (33). Place hose clamp (34) over end of 0.625-in. - (1 5.9-mm-) id by 18-in. - (45.7-cm-) long hose (35). Install hose to heater inlet elbow (31 ) and tighten clamp. Place coolant heater assembly (33) in powerplant compartment as shown below. Connect heater exhaust assembly (29) and install hose clamp (36) and screw (37). 10-7