TM-9-2350-311-34-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 233 of 352
TM 9-2350-311-34-1 1 Assemble electrical leads as required (TM 9-2350-311-20-1). NOTE Refer to electrical wiring diagram for installation of leads. 2 Solder lead (56) to capacitor board (59) (TB SIG 222). 3 Solder three leads (57) to capacitor board (55) (TB SIG 222). Acetone solvent is toxic and flammable. Use only in well-ventilated area. Do not breathe vapors. Do not use near open flame or excesive heat. Failure to heed warning could cause serious injury or even death. NOTE Step 4 applies only if capacitor boards (55 and 59) are used. 4 Clean two capacitor boards (55 and 59) with acetone solvent to remove remains of pressure-sensitive tape. 5 Install two strips of pressure-sensitive tape to each capacitor board (55 and 59). Do not remove protective coating. 6 Clean housing (56) mounting surface with acetone solvent. 7 Remove protective coating on tape and install two capacitor boards (55 and 59) as shown below. 7-97