8 9 10 11 12 TM 9-2350-311-34-1 Remove nut (36) and Iockwasher (37) from ground terminal (38) and disconnect two wire leads (39). Discard Iockwasher. Remove three screws (40), three washers (41), three Iockwashers (42), and negative bus bar (12). Discard Iockwashers. Remove two washers (43), two Iockwashers (44), two nuts (45), and ground terminal (38). Remove three screws (46), three washers (47), three Iockwashers (48), and positive bus bar (13). Discard Iockwashers. Remove nut (49), flat washer (50), screw (51), and Iockwasher (52). Discard Iockwasher. 7-93