TM 9-2350-311-34-1 7-15 RECTIFIER (M109A2/M109A3) — CONTINUED c. Assembly — Continued 8 9 10 Solder electrical leads to connection points except capacitor board assemblies (50 and 53). Acetone solvent is toxic and flammable. Use only in well-ventilated area. Do not breathe vapors. Do not use near open flame or excessive heat. Failure to heed warning could cause serious injury or death. Clean mounting surfaces with acetone solvent and install capacitor board assemblies (57 and 60) using pressure-sensitive tape. Solder electrical leads to connection points (TB SIG 222). 7-88