TM-9-2350-311-34-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 169 of 352

10 11 12 TM 9-2350-311-34-1 Disconnect connector (9) from “Y” connector (44) and disconnect connector (21 ) from accessory control box- to-heater/blower wiring harness (45). Disconnect connector (17) from in-tank fuel pump lead assembly and disconnect connector (20) from 'Y“ connector-to-in-tank fuel pump lead assembly. Disconnect two connectors (19 and 22) from flame heater electrical lead (46). b. Disassembly 1 Remove electrical tape only for sections being disassembled. 2 Separate/isolate wiring harness branches. 3 Disassemble wiring harness branches (TM 9-2350-311-20-1). c. Assembly 1 Assemble wiring harness branches (TM 9-2350-311-20-1). 2 Apply electrical tape only for sections being assembled. 7-33