TM-9-2350-311-34-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 115 of 352
TM 9-2350-311-34-1 13 Install two new seals (11) and motor assembly (10) to impeller housing (39). 14 Remove screw (7) and connect ground lead (8). Reinstall screw. 15 Connect electrical lead (6) to connector (5). 16 Slide electrical lead insulator (4) toward connector (5). 17 Install motor cover (3), 10 new Iockwasher (2), and 10 screws (1). 18 Bench test air cleaner blower motor assembly using 24-V power source. If working correctly, install in vehicle (TM 9-2350-311-20-1) and test. If not working, disassemble and repair. 5-33