TM-9-2350-311-20-2 Maintenance Manual Volume 2 for M109 Cab Download
Page 804 of 828
TM 9–2350–311–20–2 J–4 Change 2 NOTE Perform steps 9 and 10 if pipe nipple and quick disconnect coupling have not been installed on pump. 9 Apply teflon pipe sealant to threads of pipe nipple (21). Install pipe nipple in outlet port on electric hydraulic pump (22). 10 Connect quick disconnect coupling (23) to pipe nipple (21). 11 Attach one end of hose assembly (24) to cylinder support assembly (1) and quick disconnect coupling (23). NOTE Hand pump hydraulic fluid capacity is 2 gallons (7.4 l) Electric hydraulic pump fluid capacity is 3/4 gallon (2.8 l). 12 Fill electric hydraulic pump (22) reservoir with hydraulic fluid (item 20.1, Appx D) to the proper level. 13 Connect electric hydraulic pump (22) to an electrical power source. 1 24 21 22 23