TM-9-2350-311-20-2 Maintenance Manual Volume 2 for M109 Cab Download

Page 689 of 828

TM 9–2350–311–20–2 Change 2 18–19 a. Leveling Gun Trunnions NOTE All quadrant seats must be wiped clean before positioning gunner’s quadrant on them for taking readings. If cannon is not equipped with muzzle flats, use gun tube leveling fixture. 1 Bring cannon to zero elevation using M1A1 gunner’s quadrant (1) (end-for-end correction applied) on the flat of the muzzle end of tube (2). 2 Place M1A1 gunner’s quadrant (1) with zero reading (end-for-end correction applied) on breech ring quad- rant seats (3). 3 Level gun trunnions by traversing cab left or right until bubble (4) is centered. 2 3 4 1 TOP SURFACE BOTTOM SURFACE 1 1 GUN TUBE LEVELING FIXTURE