TM-9-2350-311-20-2 Maintenance Manual Volume 2 for M109 Cab Download
Page 650 of 828
TM 9–2350–311–20–2 17–12 17–3 M2A2 AIR PURIFIER AND BRACKET — CONTINUED f. Installation 1 Position angle bracket (14) on right front cab wall and secure with four new lockwashers (13) and four cap screws (12). 2 Install ground lead (5) on top of M2A2 air purifier (9) using new lockwasher (8) and machine screw (7). 3 Lift strap (11), install M2A2 air purifier (9) in angle bracket (14) and secure with strap. 4 Install remaining end of ground lead (5) at M27 periscope box (6) using new lockwasher (4) and cap screw (3). 5 Plug NBC power lead assembly (10) into connector (19) on lower side of M2A2 air purifier (9). 6 Connect four hoses (1) to air outlets (2). 1 2 7 8 5 11 10 6 3 4 5 14 13 12 9 19