TM-9-2350-311-20-2 Maintenance Manual Volume 2 for M109 Cab Download

Page 509 of 828

TM 9–2350–311–20–2 9–7 b. Installation 1 Install ring segment (15) using eight new self-locking screws (13) and eight flat washers (14). Repeat step for other ring segment. 2 Install harnesses (11 and 12) using ten machine screws (10). 3 Install power cable (8) on bus bar terminal (9) using two machine bolts (5), two new lockwashers (6), and two hex nuts (7). 4 Install ring segment shield (4) using six cap screws (1), six flat washers (2) and six new self-locking nuts (3). Repeat step for other ring segment shield. c. Testing Operate cab electrical system. 8 9 HARNESSES AND POWER CABLE 12 11