TM-9-2350-311-20-2 Maintenance Manual Volume 2 for M109 Cab Download

Page 434 of 828

TM 9–2350–311–20–2 8–10 8–1 WIRING HARNESS AND CABLE REPAIR — CONTINUED h. Terminal-Type Cable Connectors 1 Disassembly Cut and discard connector. 2 Assembly (a) Strip cable insulation equal to depth of terminal (1) well. (b) Slide insulator (2) over cable (3). (c) Insert cable (3) into terminal (1) well and crimp. (d) Slide insulator (2) over crimped end of terminal (1). 3 2 1 i. Female-Type Cable Connector with Washer 1 Disassembly Cut and discard connector. 2 Assembly (a) Strip cable insulation approximately 1/8 inch (3.2 mm). (b) Slide shell (1) and washer (2) over cable (3). (c) Place cable (3) in cylinder end of terminal (4) and crimp. (d) Slide shell (1) and washer (2) over terminal (4). 3 1 2 4