TM 9–2350–311–20–2 6–77 b. Installation CAUTION When installing any hydraulic fitting, tighten fitting to aline with the connecting lines. Repositioning can loosen threads, cause leaks, and damage preformed packings. For installation, follow illustration and legend as a guide. After installation, check hydraulic fluid level (para 6–2). 1 2 3 4 4 3 1 2 LEGEND: 1. Preformed packing (2) 2. Adapter (2) 3. Clinch sleeve (2) 4. Coupling nut (2)