TM-9-2350-311-20-2 Maintenance Manual Volume 2 for M109 Cab Download

Page 139 of 828

TM 9–2350–311–20–2 3–30 3–3 TROUBLESHOOTING CHART — CONTINUED c. CAB TRAVERSING SYSTEM — CONTINUED HYDRAULIC FILTERS AIR LINE FILTER HYGROSCOPIC BREATHER MAIN ACCUMULATOR POWER PACK ASSEMBLY SIGHT GAGE ASSEMBLY CLUTCH VALVE POWER RELAY BOX ASSEMBLY GUNNER’S SELECTOR SWITCH BOX ASSEMBLY SLIP RING ELEC- TRICAL CONTACT HOLDER BYPASS VALVE ASSEMBLY AND SOLENOID HYDRAULIC MOTOR GUNNER’S CONTROL ASSEMBLY (LEFT) CAB TRAVERSING SYSTEM (M109A4/M109A5 HOWITZERS) ELECTRICAL CONTROL CIRCUIT PUMP PRESSURE – 925 TO 1225 PSI (6378–8446 kPa) DRAIN RESERVOIR PRESSURE, 0 PSI (0 kPa) OPERATING PRESSURE 900 PSI (6206 kPa)