TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 87 of 1275

TM 9-2350-311-20-1 ITEM NO. 29 INTERVAL Annual ITEM TO BE INSPECTED Transmission Gearcase PROCEDURE f. Place combat override switch on (TM 9-2350-311-10) and engage starter for 5 seconds or less. If starter does not operate, troubleshoot starter protection circuit (para 3-3). g. Release combat override switch to off. Release fuel shutoff handle and attempt to start engine. If starter engages before 2.0 to 2.8 minutes have elapsed since step b, troubleshoot starter protection circuit (para 3-3). WARNING Oil is hazardous waste and must be disposed of in accordance with local procedures or direction of local Hazardous Waste Management office. Dry-cleaning solvent (P-D-680) is toxic and NOT FULLY MISSION CAPABLE IF: flammable. Wear protective goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes, and don’t breath vapors. Do not use near open flame or excessive heat. The flashpoint for type #1 is 100°F (38°C) and for type #2 is 138°F (59°C). If you become dizzy while using dry-cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes with water and get medical aid immediately. CAUTION Transmission holds approximately 48 or 56 qt (45 or 53 L) of oil. Before draining, provide enough container capacity to hold oil being drained. NOTE Only drain if directed by Army Oil Analysis Program (AOAP), this would be done while powerplant is removed. 2-39