TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 868 of 1275

TM9-2350-311-20-1 9-7 TRANSMISSION OIL SAMPLING COMPONENTS This task covers: a. Removal b. Installation INITIAL SETUP TOOIS General mechanic’s tool kit (item 64, Appx H) a. Removal 1 Remove tube assembly (1) from sampling valve adapter (2) and transmission adapter (3). 2 Remove adapter (3) and bushing (4) from pipe plug port hole (5). Install plug at transmission port to avoid contamination of transmission oil. 3 Remove adapter (2). 4 Loosen sampling valve locknut (6) on mounting bracket (7) marked "TRANS”. Remove sampling valve (8). b. Installation 1 Install sampling valve (8). Tighten sampling valve locknut (6) marked "TRANS” on mounting bracket (7). 2 install adapter (2) to sampling valve (8). 3 Remove plug and install bushing (4) and adapter (3) in pipe plug port hole (5). 4 Install tube assembly (1) to transmission adapter (3) and sampling valve adapter (2). 9-13