TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 842 of 1275
TM 9-2350-311 -20-1 b. c. d. 5 Disconnect terminal (14) at bilge pump circuit breaker (15) by removing nut (16). Disassembly Disassemble lead assembly (para 2-13). Assembly Assemble lead assembly (para 2-13). Installation 1 2 3 4 5 Connect terminal (14) at bilge pump circuit breaker (15) by installing nut (1 6). Install connector (13), four screws (12), four washers (11 ), four new Iockwashers (10), and four nuts (9) to bulkhead (8). Connect power lead wiring harness (7) to bulkhead (8). Connect connector (3) at master relay (6). Install two batteries (4) and clamp (5). NOTE FOLLOW-ON MAINTENANCE: Connect batteries para 8-28) 8-197