TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 826 of 1275

TM9-2350-311-20-1 b. c. d. 4 Disconnect connector (5) at air cleaner blower motor lead wire 415 (9). 5 Remove five screws (10), five Iockwashers (11), five washers (12), and five straps (13). Remove wiring harness (14). Discard Iockwashers. Disassembly/Repair Disassemble (para 2-13). Assembly Assemble (para 2-13). Installation 1 Install connector (5) at air cleaner blower motor lead wire 415 (9). 2 Install two connectors (3 and 4) at neutral safety switch (8). 3 Install connector (2) wire 415 at circuit breaker (7). 4 Install connector (1) at air cleaner blower motor relay (6). 5 Install wiring harness (14), five straps (13), five washers (12), five new Iockwashers (11), and five screws (10). FOLLOW-ON MAINTENANCE: NOTE Connect batteries (para 8-28) Install portable instrument panel (8-17) 8-181