TM 9-2350-311 -20-1 8-66 ACCESSORY CONTROL BOX VENTILATOR BLOWER SWITCH-TO-CIRCUIT BREAKER LEAD — CONTINUED a. b. c. d. Removal 1 Remove screw (1) from switch (2). 2 Remove ventilator blower switch-to-circuit breaker lead (3) from circuit breaker (4). Disassembly Disassemble (para 2-13). Assembly Assemble (para 2-13). Installation 1 Install ventilator blower switch-to-circuit breaker lead (3) to circuit breaker (4). 2 Install terminal (5) on switch (2) with screw (1). FOLLOW-ON NOTE MAINTENANCE: Install accessory control box (para 8-20) 8-170