TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 752 of 1275

TM 9-2350-311-20-1 d. Installation Ensure MASTER switch is OFF when working on hull electrical system to avoid electrical shocks and bums. NOTE On vehicles with engine model 7083-7396, connectors 14, 15, and 16 are part of connector 22 and are used for the flame heater system. On vehicles with engine model 7083-7391, connectors 14, 15, and 16 are part of connector 22 and are used for the glow plug controller system. Access to wires 10 thru 12 will be through driver's compartment. 1 Install powerplant wiring harness. 2 install two clamps (29), two screws (28), two clamps (27), and two screws (26). 3 Install two leads (13 and 9) at starter solenoid (25). Install two flat washers (24) and two nuts (23). 4 Connect 11 electrical connectors (1 thru 8 and 10 thru 12). 5 Connect five electrical connectors (18 thru 22). NOTE FOLLOW-ON MAINTENANCE: Close transmission access doors (para 11 -7) Install engine access cover (para 11-5) Connect batteries (para 8-28) Close air intake grille (para 11 -8) 8-107 WARNING