TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 742 of 1275
TM 9-2350-311-20-1 a. Removal 1 Remove four screws (1), four Iockwashers (2), and guard assembly (3). Discard Iockwashers. 2 Remove two screws (4), two Iockwashers (5), and bus bar (6) from external power receptacle (7). Discard Iockwashers. 3 Remove screw (8) and Iockwasher (9). Disconnect cable (10) and remove insulating boot (11). Discard Iockwasher. 4 Remove four screws (12), four flat washers (13), and protective cover (14) with cable (16) from receptacle. 5 Remove receptacle (7) and gasket (15). Discard gasket. b. Installation 1 Install new gasket (15) and external power receptacle (7). 2 Install protective cover (1 4), four flat washers (13), and four screws (1 2). Ensure protective cover cord (16) is attached under one screw. 3 Wrap exposed wire connections with electrical tape. 4 Install insulating boot (11 ), cable (10), new Iockwasher (9), and screw (8). 5 Install bus bar (6), two new lockwashers (5), and two screws (4). 6 Install guard assembly (3), four new Iockwashers (2), and four screws (1). NOTE FOLLOW-ON MAINTENANCE: Connect batteries (para 8-28) 8-97