TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 729 of 1275
TM 9-2350-311-20-1 8-31 STARTER RELAY BOX — CONTINUED b. Installation 1 2 3 WARNING Ensure MASTER switch is OFF when working on starter switch relay boxes to avoid electrical shocks and bums. Remove two nuts (2), two Iockwashers (3), two screws (6), four external-tooth Iockwashers (4), and two flat washers (5). Secure bilge pump relay (8). Discard Iockwashers and external-tooth Iockwashers. Install starter relay box or starter protection relay box (7), two new Iockwashers (3), four new external-tooth Iockwashers (4), two flat washers (5), two screws (6), and two nuts (2). Connect electrical connector (1). 8-32 BILGE PUMP CIRCUIT BREAKER This task covers: a. Removal b. Installation INITIAL SETUP General mechanic’s tool kit (item 64, Appx H) Lockwashers (2) (item 86, Appx G) Tools 8-84