TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 656 of 1275
TM 9-2350-311-20-1 b. Installation 1 2 3 4 5 NOTE A good ground is essential to prevent radio static and to permit starter relay and bilge pump to operate. Install voltage regulator (3) on mount (8). Install strap (13). Install four flat washers (10), four new lockwashers (11), four voltage regulator mounting screws (9), and four nuts (12). Install mount (8) with regulator (3), four flat washers (5), four new lockwashers (6), four screws (4), and four nuts (7). Install two wiring harness connectors (1 and 2) at voltage regulator (3). NOTE FOLLOW-ON MAINTENANCE: Connect batteries (para 8-28) 8-4 RECTIFIER (M109A2/M109A3) This task covers: a. Removal b. Installation M109A2/M109A3 Lockwashers (2) (item 81, Appx G) Preformed packing (item 60, Appx G) T OO I S Silicone compound (item 31, Appx D) General mechanic’s tool kit (item 64, Appx H) Torque wrench (item 72, Appx H) Equipment Conditions Batteries disconnected (para 8-28) 8-11