TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 563 of 1275
TM 9-2350-311 -20-1 6-3 FUEL TANK LEVEL TRANSMlTTERS (UPPER AND LOWER) — CONTINUED b. Installation Do not smoke or use open flame when working on fuel system. An explosion may occur, causing severe injury or death. 1 Install new gasket (23) and transmitter (22). 2 Install ground lead (21), five washers (20), and five screws (19). 3 Install electrical connector (1 8). 4 Install plate (1 7), two flat washers (1 6), and two nuts (1 5). 5 Install bar (1 4), flat washer (1 3), screw (1 2), six washers (11), and six nuts (1 O). WARNING