Page 505 of 1275

TM 9-2350-311-20-1 4-5 POWERPLANT — CONTINUED e. Special Equipment Removal — Continued 17 Disconnect two electrical connectors (86) from voltage regulator (88). 18 Disconnect two electrical connectors (86) from master relay (87). 19. Disconnect hose assembly (157) and adapter from quick disconnect (73) on primary fuel filter input hose (72). 20 Disconnect quick disconnect and hose assembly (155) from fuel return hose (47). 4-44