TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 423 of 1275
TM 9-2350-311 -20-1 CONTINUED FROM STEP E F . 3. 4. 5. Reconnect lead 450 to circuit breaker output. Disconnect lead 450 of driver’s instrument panel wiring harness from connector near circuit breaker. Place red lead of multimeter in lead 450 and black lead to ground. Turn MASTER switch ON and check for voltage. Turn MASTER switch OFF. is voltage present? r I Repair or replace lead 450 of driver’s instrument panel wiring harness (para 8-51). Repair or replace lead 509E of bulkhead-to-portable instrument panel wiring harness (para 8-49). END OF TASK 3-323