TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 389 of 1275

TM 9-2350-311-20-1 CONTINUED FROM STEP E 1. 2. 3. 4. 5. 6. Reconnect lead 10 of power lead assembly to accessory control box. Remove accessory control box cover (para 8-20). Disconnect lead 10A from circuit breaker input. Place red lead of multimeters in lead 10A and black lead to ground. Turn MASTER switch ON and check for voltage. Turn MASTER switch OFF. I Is voltage present? Repair or replace lead 10/10A of accessory control box wiring harness (para 8-53). 1. Reconnect lead 10A to circuit breaker input. 2. Disconnect lead 400A from circuit breaker output. 3. Place red lead of multimeters in circuit breaker output and black lead to ground. 4. Turn MASTER switch ON and check for voltage. 5. Turn MASTER switch OFF. I Is voltage present? Replace circuit breaker (para CONTINUED ON NEXT PAGE 3-289 8-20).