TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 379 of 1275

TM 9-2350-311-20-1 CONTINUED FROM STEP A 2. 3. 4. 5. Reconnect bulkhead-to-driver’s instrument panel wiring harness to light switch. Disconnect lead 40 of bulkhead-to-driver’s instrument panel wiring harness form “Y” connector. Place red lead of multimeters in lead 40 and black lead to ground. Turn MASTER and instrument panel light switches ON and check for voltage. Turn MASTER and instrument panel light switches OFF. Is voltage present? Replace “Y connector (para 8- 52). Repair or replace lead 40 of bulkhead-to- driver’s instrument panel wiring harness (para 8-50). END OF TASK 3-279