TM 9-2350-311-20-1 CONTINUED FROM STEP A F 1. Install inoperative panel light bulb (para 8-1 7). 2. Disconnect bulkhead-to-driver’s instrument panel wiring harness from main light switch. 3. Place a jumper wire from socket F (lead 15) to socket B (lead 40). 4. Turn MASTER and instrument panel light switches ON and check all instrument panel lights for operation. 5. Turn MASTER and instrument panel light switches OFF. I Do all panel lights operate? Replace light switch (para 8-17). I 1. Reconnect bulkhead-to-driver’s instrument panel wiring harness to light switch. 2. Disconnect lead 40 of bulkhead-to-driver’s instrument panel wiring harness form “Y” connector. 3. Place red lead of multimeters in lead 40 and black lead to ground. 4. Turn MASTER and instrument panel light switches ON and check for voltage. 5. Turn MASTER and instrument panel light switches OFF. Is voltage present? I Replace “Y” connector (para 8-52). Repair or replace lead 40 of bulkhead-to- driver’s instrument panel wiring harness (para 8-50). END OF TASK 3-277