TM 9-2350-311-20-1 1. Reconnect lead 324 to transmission oil B temperature transmitter. 2. Disconnect lead 324 from TRANSMISSION OIL TEMP gage. 3. Turn MASTER switch ON and check TRANSMISSION OIL TEMP gage for a reading. 4. If TRANSMISSION OIL TEMP gage shows a maximum reading, use a jumper wire to ground gage. 5. Check gage for reading. 6. Turn MASTER switch OFF. Does TRANSMISSION OIL TEMP gage show minimum when grounded, and maximum when not grounded? c 1. Reconnect lead 324 to TRANSMISSION OIL TEMP gage. 2. Disconnect lead 27 from TRANSMISSION OIL TEMP gage. 3. Place red lead of multimeters in lead 27 and black lead to ground. 4. Turn MASTER switch ON and check for voltage. 5. Turn MASTER switch OFF. Is voltage present? 3-203